Categories: ,

HIKVISION DS-UPS03K72

$474

Available in Harare
Not available in Bulawayo

In stock

  • Double conversion on-line design with input power factor correction (PFC) technology, achieving an input power factor of up to 0.99.
  • Digital control system for enhanced stability and reliability.
  • ECO operation mode for improved energy efficiency and reduced user costs.
  • Three-stage charging: constant current charging, constant voltage charging, and floating charging stages are intelligently managed.
  • Wide voltage input and frequency range for stable operation with different electrical scenario, and suit with various fuel generators.
  • Comprehensive protections including output overload, output short-circuit, over-temperature, battery under-voltage warning, battery over-charging protection, and power-on self-diagnostic function;
    • Power
    • UPS Capacity 3000 VA / 2700 W
    • Input
    • Nominal Voltage208/220/230/240Vac
    • Input Voltage Range110~300Vac (176~264Vac @ 100% load)
    • Input Frequency40~70Hz (50/60Hz Auto-Sensing)
    • PhaseSingle Phase
    • Power factor≥0.99
    • Output
    • Output Voltage208/220/230/240Vac
    • Output WaveformPure Sinewave
    • Power factor 0.9
    • Output SocketsOptional: IEC panel/EU panel/UK panel/US panel
    • Output Frequency

      Online mode: 46~54Hz or 56~64Hz

      Bat. Mode: (50/60±0.1%)Hz

    • Crest factor3:1
    • Harmonic distortion (THDv)

      ≤3% Linear load

      ≤5% Non linear load

    • Transfer Time

      AC mode to Bat.mode: 0ms

      Inverter to Bypass: 4ms (Typical)

    • Battery
    • Battery TypeValve Regulated Lead Acid (VRLA)
    • Typical Recharging Time4 hours (To 90% of full capacity)
    • Capacity (Standard Unit)12V/9Ah
    • Battery Number6
    • DC System Voltage (VDC)72V
    • Charging Current (Max.)1A
    • Expandable RuntimeYes, External battery pack: DS-UPSB0972B-R/TJC
    • Typical Backup TimeView Runtime Graph
    • Indicator
    • LCD displayInput voltage, Input frequency, Output voltage, Output frequency, Load percentage, Battery voltage, Inner temperature & Remaining battery backup time
    • AlarmBattery mode/Battery low voltage /Overload/Fault
    • Efficiency
    • AC Mode92%
    • Battery Mode88%
    • Environment
    • Operating Temperature0℃~40℃
    • Storage Temperature-25℃~55℃
    • Humidity Range20~95%RH @ 0~40℃ (Non condensing)
    • Altitude<1500m, derating required when>1500m
    • Noise Level<55dB at 1 Meter
    • Physical
    • Dimension W x D x H (mm)440 x 600 x 86.5
    • Net weight (kg)26
    • Standards
    • SafetyIEC/EN 62040-1, IEC/EN 62477-1
    • EMCIEC/EN 62040-2, IEC61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC61000-4-5, IEC61000-4-6, IEC61000-4-8

In stock